Gelöscht
本帖最后由 阿东先生 于 2013-7-6 07:27 编辑Gelöscht 1.从未试过在windows下嗅探,所以keine ahnung。不知道你在linux下的sniffer是否运行正常?
2.两种办法:
a,使用partitionmagic之类的软件重新划分分区;
b,直接用linux的fdisk修改d,e,f,g中任意一个分区的type号,比如"a5" for freebsd, "a6" for openbsd,或者 "a9" for netbsd etc...将bsd系统安装在这个分区中。
ps.如果不用vmware,建议你安装bsd之前做一张linux引导盘。以免mbr被bsd引导占用后无法启动windows和linux。 linux下正常的,就是想试一下有名的NETXRAY和SNIFFER PRO而已。
谢谢 就问题1.
PC, Windows 2000 Professional . 2块网卡, Realtek 8029. SiS 900 PCI.
刚刚测试, NETXRAY 3.3 ,程序启动,报错说找不到网卡. 最近非常忙,没有时间再研究了.
希望对你有帮助. 在国内的机器上用8029也试过,也是同样的报错,不知道为什么。有没有装成功的兄弟啊??
我快看遍网上文档了,最后还是觉得软件本身自带的文档比较有用,但是实在不明白到底和里面哪条有抵触,我把文档帖出大家研究研究:
2.4NetXRay displays Open Adapter Failure during startup.
The following are known causes and remedies for the Open Adapter failure.
Cause: If you accidentally installed the Network adapter driver more than once, NetXRay may pick the wrong driver that fails to open. To confirm that there are two identical drivers installed, Go to Control Panel/System, select Device Manager page, expand the Network Adapter listing. You should see two or more identical drivers listed. Or when you see two identical drivers in NetXRay's Select Network Adapter dialog box.
Remedy: Remove the identical drivers, and re-install your network driver from scratch cleanly.
Cause: If you accidentally installed the Network adapter driver more than once, NetXRay Select Adapter dialog box show two or more identical drivers listed. But Control Panel/Network dialog box only show one driver. Selecting the second driver causes open adapter Open error.
Remedy: The second entry is caused by prior incomplete installation of the NIC card. Somehow the Win95 Registry is left with two of the same entries.
To remove the second one from Windows 95 Registry execute the following:
1. Bring up DOS Prompt.
2. Type: REGEDIT<cr>
3. Select
My Computer\HKEY_LOCAL_MACHINE\System\CurrentControlSet\Services\Class\Net
4. Open each entry 0000, 0001, 0002, etc. to find the duplicated entry. Delete the second one.
Now netxray should only see one.
Cause: If you migrated your Win 95 PC from an existing Windows for Workgroup 3.11 and were using the Microsoft DLC stack, NetXRay may experience an Open Adapter failure.
Remedy: Go to Control Panel/Network, select the Microsoft DLC stack, and remove it.
Cause: If you migrated your Win 95 PC from an existing Windows 3.1 and were using 16 bit NDIS driver, NetXRay may experience Open Adapter failure.
Remedy: Go to Control Panel/Network, select the NDIS 2.0 driver and remove it.
Cause: NetXRay supports only Enhanced mode 32 bit driver, if you selected Real mode 16 bit NDIS or ODI driver support for your network adapter, NetXRay may experience Open Adapter failure.
Remedy: Go to Control Panel/Network, select your network adapter card, and click Property button. Select Enhanced Mode Driver.
Cause: If you purchased NetXRay for NT system and try to run it in Windows 95, NetXRay will experience an Open Adapter failure.
Remedy: Contact the reseller or Cinco Networks where you purchased NetXRay from and purchase a Windows 95 version.
Cause: If you use a IBM Tropic chipset based Token Ring adapter, it does not support promiscuous mode andwill cause NetXRay Open Adapter failure.
Remedy: None. User recommended Madge or Olicom NIC card.
Cause: If you use Madge Token Ring adapter, and have promiscuous mode turned off as in default mode, NetXRay will experience Open Adapter failure.
Remedy: See section 2.1 of the readme file about how to enable Madge card promiscuous mode.
页:
[1]